FLTM BO 116-01_2007
點擊次數:1311 更新時間:2019-08-27

FLTM BO 116-01_2007

本頁面標準信息均來源于網絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結果的準確性、節省您的時間,如需FLTM BO 116-01_2007標準詳細信息或FLTM BO 116-01_2007具體測試方法,請與我們技術人員聯系或給我們留言,我們將為您提供相關的技術支持。

 

FLTM-BO-116-01標準簡介

FLTM-BO-116-01 汽車內飾材料暴曬試驗標準:水冷式氙弧燈氣候試驗箱方法

FLTM  BO 116-01_2007標準英文版

EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

FLTM BO II--01_2007測試機構

 

pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

上一篇:GB 16776-2005

下一篇:ETAG 002-1999

返回列表>>

粵公網安備44190002001386號

主站蜘蛛池模板: 国产精品亚洲视频 | 国产高清一区二区三区 | 毛片一级在线 | 在线观看一区二区三区四区 | 久久av一区二区三区 | 国产高清在线精品一区二区三区 | 国产精品久久久久久久久久小说 | 91国内外精品自在线播放 | 国产精品影视 | 日韩视频在线免费播放 | 亚洲精品国产一区 | 国产精品高清一区二区 | 激情国产 | 久久亚洲一区二区 | 亚洲日韩中文字幕在线播放 | 久久久精品久久久 | 亚洲精品99 | 国产一区二区三区免费观看 | 亚洲精美视频 | 亚洲aⅴ天堂av在线电影软件 | 国产精品资源在线 | 91精品国产综合久久久久久漫画 | 黄色成人在线 | 久久久亚洲精 | 玖玖综合网 | 91中文在线 | 精品无码久久久久国产 | 国产a视频| 国产一区二区在线免费观看 | 欧美午夜一区二区三区免费大片 | 精品一区二区久久久久久久网站 | 久久中文字幕一区二区 | 亚洲欧美一级久久精品国产特黄 | 国产色 | 波多野结衣一区二区三区中文字幕 | 亚洲黄色特级片 | 91婷婷射| 久日av| 91天堂| 一区二区三区日韩在线 | 日韩精品专区在线影院重磅 |